Dnipro Metiz Work LLC

Steel Wire, Fiber, Pipes Production and Sales

+38 067 632-95-93 +38 067 650-62-62

Steel fiber EN 14889-1:2006


52 UAH
Buy

Steel anchoring fibre is a product made from high-strength steel wire with a tensile strength of at least 1100 MPa, specially designed to be used to reinforce concrete structures, in an amount of 20 to 25 kg per cubic metre of concrete mortar.

We will inform you of the actuial price EUR/ton and delivery time upon request by e-mail dmz.sales@ukr.net 

WhatsApp +380676329593

Steel anchor fibres are an alternative to traditional concrete reinforcement methods, such as reinforcement cages and masonry mesh. The fibres are distributed evenly throughout the concrete mass, providing more uniform support and increased tensile and flexural strength. This reduces material and construction costs, especially where large masses of concrete are needed - floors, roads, tunnels, and more. Construction time is reduced by 30-40%.  

We offer steel fibres in different sizes and strengths for different projects.

Technical specification of steel fibers

d- fiber diameter, mm

l - fiber length, mm

λ - ratio l/d

h – heigh of hooked end, mm

ℓ´, ℓ´* - Length of hooked end, mm

”, ”* - anchor length, mm

α’, α″ - bending angle, degrees

Fiber quantity in 1 kg, pcs.

0.6±0.03

32.0±1.5

53±4

2.4±0.5

5.0±1.9

>1

45±10

~ 14075

0.75±0.03

52.0±2.0

69±4

3.1±0.3

5.0±1.9

>1

45±10

~ 5545

0.8±0.04

50.0±2.0

63±4

2.9±0.5

5.0±1.0

>1

45±10

~ 4894

1.0±0.04

50.0±2.0

50±3

3.1±0.5

5.0±1.0

>1

45±10

~ 3132

1.0±0.04

60.0±3.0

60±4

3.1±0.5

5.0±1.0

>1

45±10

~ 2629

 

 

 

Mechanical properties of fibers and recommended consumption rates

Type-size of steel fiber

Rm - average ultimate tensile strength of wire N / mm2

Minimum fiber content, kg per 1m3 of concrete

Е - modulus of elasticity, MPa

Impact on concrete consistency

Impact on concrete strength

60/32

1550

15

200000

Concrete hardness is 8s on the Vebe*

Concrete has a residual flexural strength of 1.5N / mm2 at CMOD = 0.5mm (crack opening width) and 1N / mm2 at CMOD = 3.5mm

60/32

1300

20

75/52

1500

20

80/50

1200

25

80/50

1500

20

1/50

1150

30

1/50

1500

20

1/60

1500

20